PRODUCT

PRODUCT

GLM-71 Blood Glucose Analyzer

Product Detail

Test Menu

Product Tags

 Blood Glucose Analyzer (1).png

Intelligent code-free

Insert the test strip and turn on the machine automatically

The design of the instrument is free of adjusting code, inserting the strips automatically card machine, fully automatic operation.

Elderly people can learn to operate it quickly.


8 seconds fast measurement

Large screen display, clear reading

8 seconds countdown timer after blood suction, the measurement result will be out in high definition.

Large subtitle display, the elderly can view the results at a glance


Micro-volume blood collection Siphon technology

Less than 1 microlitre of blood collected

Siphon technology automatically sucks blood, accurately measures blood sugar, ultra-fine needle

Ultra-fine needle, reduce the psychological burden of blood collection.


Nine-legged electrodes are safe and stable

Electrochemical biosensing technology

Adopting electrochemical biosensing and siphon technology to satisfy all powerful functions, more accurate measurement results.

The measurement result is more accurate.

Technical Specification

Blood Sample Type

Blood Sample Type Freshly collected microvascular whole blood, venous blood can be tested when used by healthcare professionals

Sample volume requirement

1 microlitre

Volume Ratio Range

25%~65%

Test range

1.1~33.3mmol/L

Testing time

8 seconds or less

Memory capacity

180 memories

Time setting

Time and date can be set

Test scenario setting

Pre-meal, post-meal and QC fluid test values can be marked.

Operating voltage

Internal battery DC 3V (two #7 dry cell batteries)

Battery life

Approx. 1000 tests (actual battery life varies depending on usage and battery brand).

High and low blood glucose warning function

Preset blood glucose value higher than 17.7mmol/L will display the high blood glucose warning symbol.

Power saving device

Auto switch off after 2 minutes of inactivity.

Operation mode

Continuous operation

Environmental conditions for transport and storage

-25℃~55℃, relative humidity 10%~80%, atmospheric pressure: 672hPa~1060hPa

Maximum working temperature of the battery

60℃

Software version

V4.2.1

Service life

10 years

Operating Methods


This product is for use with matching blood glucose test strips.

Please read the instructions for use carefully.

Insert the test strip and check that the code is the same.

Aspirate blood from the aspirate end of the test strip.

Display your results within 8 seconds.


  • Previous:
  • Next:
  • Write your message here and send it to us